Preheat Germicidal Ultraviolet Lamps

STER-L-RAY  ® Preheat germicidal lamps are operated by a preheat start circuit that employs a relatively compact and economical ballast. The preheat circuit requires four electrical connections per lamp and a slight to moderate delay is needed to start the lamp. Some modern electronic ballasts are capable of instant starting a Preheat lamp. Available in Low Ozone and Ozone Producing versions. 
 

Preheat Germicidal Ultraviolet Lamp

 

Low Ozone Ozone Producing Length (mm) Base Face to Face Lamps (Watts)(1) Approx. Lamp Current (mA) UV Output Total Watts (2) UV Output Microwatts at 1 Meter (3) Ozone Output (if applicable) (4) Rated Lamp Life (Hours)
GPH212T5L*
05-1400-R
GPH212T5VH*
05-1425-R
212 10 425 2.7 26 0.6 10,000
GPH238T5L/4
05-0198-R
GPH238T5VH/4 238 11 425 3.0 30 0.65 10,000
GPH250T5L/4
05-0364-R
GPH250T5VH/4 250 12 425 3.2 32 0.7 10,000
GPH254T5L* GPH254T5VH*
05-0130-R
254 12 425 3.3 33 0.71 10,000
GPH275T5L/4
05-0112-R
GPH275T5VH/4
05-1599-R
275 13 425 3.5 35 0.76 10,000
GPH287T5L*
05-1098-R
GPH287T5VH*
05-1053-R
287 14 425 4 40 0.9 10,000
GPH303T5L/4
05-0633
GPH303T5VH/4 303 15 425 4.3 43 0.94 10,000
GPH330T5L/4
05-0201-R
GPH330T5VH/4
05-0203-R
330 16 425 4.6 46 1.0 10,000
GPH357T5L*
05-0329-R
GPH357T5VH*
05-0159-R
357 17 425 5.7 58 1.25 10,000
GPH436T5L*
05-1097-R
GPH436T5VH*
05-1426-R
436 21 425 7.3 72 1.6 10,000
GPH450T5L/4
05-0010-R
GPH450T5VH/4
05-0011-R
450 22 425 7.5 75 1.6 10,000
GPH463T5L*
05-1531-R
GPH463T5VH* 463 23 425 8.0 78 1.7 10,000
GPH620T5L/4
05-0097A-R
GPH620T5VH/4
05-0161-R
620 30 425 10.4 104 2.2 10,000
GPH650T5L/4 GPH650T5VH/4
05-1522-R
650 34 425 11.0 109 2.4 10,000
GPH793T5L*
05-1116-R
GPH793T5VH*
05-1427-R
793 38 425 13.5 125 2.9 10,000
GPH810T5L/4
05-0176-R
GPH810T5VH/4
05-0148-R
810 39 425 13.8 130 3.0 10,000
GPH843T5L*
05-0195-R
GPH843T5VH* 843 41 425 15 136 3.3 10,000

* Also available in 4-pin single ended configurations

Other sizes are readily available. Custom lamp lengths can also be supplied. Please contact us for help with your needs. Please note that ozone output is subject to considerable variation due to conditions under which the lamp is used; under many conditions, the ozone output may be only a fraction of the specified figure.

(1) Wattage is lamp watts only and does not include ballast loss.
(2) Ultraviolet output at 254 nanometers at 100 hours and 80°F (approximate).
(3) Microwatts per square centimeter at one meter from lamp.
(4) Approximate ozone output in grams per hour under favorable conditions. Figures apply only to ozone producing types.

UVTS Enviro Control - Since 2003